01 · CONTROL CABINETS · FIRE SUPPRESSION
ANHEL® control cabinets for fire-suppression systems
Control of duty and jockey pumps that hold pressure and water reserve in fire-suppression systems — both in standby and during a fire. Automatic start on the Fire signal, priority of water for fire suppression, ATS on the supply side.

02 · Technical specifications
Series parameters
Reference characteristics. The final configuration is sized to the project brief.
Number of pumps
1 – 4Power per pump
0.37 – 500kWCurrent rating
1 – 3000ASupply voltage
380VPower supply
2 / 3 inputs with ATSClimate rating
UKhL1 – UKhL4Control type
local / remoteCertification
FZ-123 (fire safety)
03 · DESCRIPTION
Purpose and operating principle
The ANHEL® control cabinet for fire suppression drives the duty and standby pumps with automatic start on the Fire signal received from the fire control panel. It supports sprinkler and deluge algorithms, operation with foam concentrate for class-B fires, and priority of water for fire-suppression duty.
It monitors the integrity of the wiring back to the fire control panel, the pressure switches and the operator workstation. On duty-pump failure the standby pump starts automatically; on phase imbalance, phase loss or voltage deviation the cabinet transfers to the backup feed. Overload and short-circuit protection of the motors comes as standard.
04 · APPLICATIONS
Where it is deployed
Water and foam fire-suppression systems for residential, commercial and industrial sites.
Deluge systems
Curtains, compartments, areas with high occupancy
Sprinkler systems
Targeted suppression in commercial and warehouse property
Foam suppression
Class B — petroleum products, fuel depots, flammable-liquid stores
Combined systems
Domestic water + fire-water supply
Industrial sites
Plants, warehouses, power-generation facilities
Residential complexes
Internal fire-water mains in high-rise housing, car parks
06 · ADVANTAGES
Why ANHEL®
FZ-123 fire-safety certification, reliability in emergencies and integration with fire alarm systems.
FZ-123 fire-safety certification
Conformity with Russian fire-safety regulations — a mandatory requirement for automatic fire-suppression systems.
Auto-start on the Fire signal
Direct input from the fire control panel, pressure switches and damper-position relays; monitoring of line integrity with open-circuit and short-circuit diagnostics.
ATS on 2 or 3 supply inputs
Automatic transfer on phase imbalance, phase loss and voltage deviation — without operator intervention.
Pump redundancy
Automatic start of the standby pump on duty-pump failure, with water-presence monitoring at each pump inlet.
Orion and Rubezh integration
Off-the-shelf variants for embedding into the site's existing fire alarm system.
GOST assembly and full documentation pack
Certificates, declarations and passports included. Designer support during the solution-development stage.
07 · GALLERY
From the factory floor
Photos will be published after retouching of the factory shots.
08 · PROJECTS
Already in use at
10 · DOCUMENTATION
Documents and specification sheet
Specification sheet — PDF for design and acceptance, or online form with autosave.