01 · PUMPING STATIONS · FIRE PROTECTION
ANHEL pumping stations for fire-protection systems
Units that maintain the required pressure and flow in the fire-protection system both on standby and during the increased demand of a fire response. Automatic start, hot redundancy and a complete set of regulatory documentation.

02 · Technical specifications
Series parameters
Reference characteristics. The final configuration is sized to the project brief.
Number of pumps
2 – 6standardDOL control
with controller / with soft starterVFD control
with controller / per-pump / with soft startMax. fluid temperature
70°CMains voltage
3 × 380VPower per pump
0.37 – 250kWRotation speed
2900 / 1450rpmDesign life
min. 10years
03 · DESCRIPTION
Purpose and operating principle
ANHEL fire-protection pumping stations maintain the required pressure and flow in sprinkler, hydrant and combined fire-protection systems. Automatic start on a signal from the fire alarm panel or on a system pressure drop, hot redundancy and condition monitoring on every pump.
The unit is built on a single frame with a control cabinet and a full set of shut-off valves. The configuration — number of pumps, working pressure, control modes — is selected from the project parameters.
04 · APPLICATIONS
Where it is deployed
From residential complexes to infrastructure facilities. Every unit is built to the project.
Residential complexes
Dmitrovsky Park residential complex, Moscow
Office buildings
Class-A office, 20+ floors
Shopping centres
Shopping centres with covered car parks
Industrial sites
Warehouses, production halls
Hotels
4–5★ hotels, apart-hotels
Infrastructure facilities
Airports, railway stations, stadiums
05 · BRANDS
Built from globally recognised equipment
Pumps from proven manufacturers; automation in-house and imported.
06 · ADVANTAGES
Why ANHEL®
Serial production, quality control and our own automation.
Serial production
Professional assembly cycle — not improvised on-site assembly.
Built to design brief
Assembly to the client's brief, flexible project-specific configuration.
Quality control
Every station undergoes hydraulic and electrical testing before shipment.
Multiple control modes
DOL, VFD, controller with soft start — matched to the site's duty.
Reliability and long service life
Full average service life of at least 10 years in normal operation.
Complete documentation set
Regulatory and operational documents — all certificates and passports supplied.
07 · GALLERY
From the factory floor
08 · PROJECTS
Already in use at
10 · DOCUMENTATION
Documents and certificates
EAEU Conformity Declaration, specification sheet and manual — for design and acceptance.