01 · PUMPING STATIONS · HEATING AND COOLING
ANHEL pumping stations for heating and cooling systems
Units that circulate heating fluid or chilled water in central heating, cooling and air-conditioning systems. Precise pressure control, motor protection and control algorithms tuned for minimum energy consumption.

02 · Technical specifications
Series parameters
Reference characteristics. The final configuration is sized to the project brief.
Number of pumps
2 – 6standardControl type
DOL / VFD / per-pump VFDwith controllerFluid temperature
0 – 120°C (on request up to 180 °C)Mains voltage
3 × 380VMax. ambient temperature
40°CPower per pump
0.37 – 90kW (standard)Rotation speed
2900 / 1450 / 970rpmUnit design life
min. 10years
03 · DESCRIPTION
Purpose and operating principle
These units circulate heating fluid or chilled water in central heating, cooling and air-conditioning systems for residential and industrial buildings. They provide precise pressure control, motor protection and control algorithms tuned for minimum power consumption.
They operate with water and water-glycol mixtures across a wide temperature range (0–120 °C, on request up to 180 °C). The control package is matched to the circuit: DOL with soft start, VFD with a controller, or per-pump VFD.
03 · APPLICATIONS
Where it is deployed
Residential and industrial buildings, central heating and cooling systems, process loops.
Heating systems
Circulation of heating fluid through pipework and radiators
Cooling supply
Central cooling for shopping centres, offices, data centres
Air conditioning
Chilled-water circulation in air-handling units
Industrial buildings
Process heating and cooling circuits
Residential complexes
Central heating and cooling in high-rise developments
Process applications
Maintaining stable operation in production circuits
04 · BRANDS
Built from equipment of leading manufacturers
Pumps — RCP, RHP, RMP, TD, KML, LPP. Automation and components — European and Russian.
05 · ADVANTAGES
Why ANHEL
Factory assembly, multiple control modes and intelligent automation with self-diagnostics.
Professional serial production
Factory assembly on a specialised OEM facility, hydraulic and electrical testing of every unit before shipment.
Built to design brief
Hydraulic parameters, pump group configuration and automation built to the project parameters.
Multiple control modes
DOL with soft start, VFD with a controller, per-pump VFD — chosen to match the system duty.
Energy-efficient design
Soft start lowers the mains load; control algorithms tuned for minimum power consumption.
Automatic deaeration
Automatic removal of air from the heat carrier — no manual maintenance. Automatic flow metering with remote readout.
Intelligent automation
Self-diagnostics, redundant control for maintenance without shutdown. 7" LCD shows the hydraulic schematic and the event log.
08 · PROJECTS
Already in use at
09 · DOCUMENTATION
Documents and certificates
Specification sheet, certificates and manual — for design and acceptance.